Battery Cell Emulator
General |
Number of cells per unit |
12 |
Number of cells in series |
Up to 252 cells for 5 V voltage output Up to 216 cells for 6 V voltage output Up to 156 cells for 8 V voltage output |
Cell-to-cell isolation |
100 V |
Cell-to-system isolation |
1.3 kV |
Power Supply |
48 V DC ± 5 % |
Power Consumption |
480 W max. |
Communication Interface |
EtherCAT |
Update rate |
Up to 1 kHz |
Cell Emulation Characteristics |
Voltage range |
Available in different voltage ranges: 0.01 V to 5 V with 18-bit resolution 0.01 V to 6 V with 18-bit resolution 0.01 V to 8 V with 18-bit resolution |
Voltage accuracy |
± 0.5 mV |
Voltage ripple |
6 mVpp |
Current range sink/source |
Up to ± 5 A (current derating above 5 V) with 18-bit resolution |
Current accuracy |
± 2 mA |
Cell power |
25 W max. (sink/source) |
Step response 0 V to 6 V |
≤ 0.5 ms without load |
Step response 6 V to 0 V |
< 0.5 ms full load |
Cell Measurement Characteristics |
Voltage range |
0 V to 10 V with 18-bit resolution (approx. 40 µV) |
Voltage accuracy |
± 0.5 mV |
Current range |
± 5 A with 18-bit resolution (approx. 40 µA) |
Current accuracy |
< ± 2 mA |
Filter response |
-3 dB cutoff frequency at 15 kHz |
Protection |
Battery cell enable (INTERLOCK) |
Globally enable for all cells |
Embedded protection |
Overvoltage, overcurrent, and overtemperature protection Short circuit and polarity reversal protection |
Physical |
Dimensions |
2U 19” subrack enclosure, depth: 350 mm |
Connectors |
2 x RJ45 connectors for communication with the real-time target machine, as well as additional Battery Cell Emulators, Fault Insertion Units, and Temperature Sensor Emulators 12 x 4-pin Mega-Fit connectors for Cell Emulation (Molex part No. 768250004) 1 x 5-pin pluggable MSTB terminal block for Power Input and INTERLOCK (Phoenix part No. 1776728) |
Weight |
- |
Environmental |
Operating temperature |
5 °C to 40 °C |
Relative humidity |
5 % to 95 %, non-condensing |
Standards Compliance |
Compliances |
CE, CB, FCC, UK CA EMC: IEC 61326-1 Safety: IEC 61010-1 RoHS, REACH |
Temperature Sensor Emulator
General |
Number of sensor emulation channels per unit |
4, 8, 12, 24, or 36 |
Channel-to-channel isolation |
100 V (for 4 channels) |
Channel-to-system isolation |
1 kV |
Power supply |
DC voltage input: 48 V DC ± 5 % |
Power consumption |
25 W max. for 4 channels An additional 10 W for each subsequent set of 4 channels |
Communication interface |
EtherCAT |
Temperature Emulation Characteristics |
Resistor range |
10 Ω to 4 MΩ |
Resolution |
1 Ω |
Accuracy |
±0.1 % ± 0.5 Ω |
Integrated fault insertion |
Emulation of open circuits and short circuits (50 mΩ) |
Power |
Max. 100 mW per channel |
Current |
Max. 10 mA |
Voltage |
Max. 20 V |
Settling time |
10 ms |
Physical |
Dimensions |
2U 19” subrack enclosure, depth: 350 mm |
Connectors |
2 x RJ45 connectors for communication with the real-time target machine, as well as additional Battery Cell Emulators, Fault Insertion Units, and Temperature Sensor Emulators 4 x, 8 x, 12 x, 24 x, or 36 x 4-pin Mega-Fit connectors for temperature emulation (Molex part No. 768250004) 1 x 5-pin pluggable MSTB terminal block for Power Input and INTERLOCK (Phoenix part No. 1776728) Refer to order information for the correct item ID, depending on the number of channels |
Weight |
- |
Environmental |
Operating temperature |
5 °C to 40 °C |
Relative humidity |
5 % to 95 %, non-condensing |
Standards Compliance |
Compliances |
CE, CB, FCC, UK CA EMC: IEC 61326-1 Safety: IEC 61010-1 RoHS, REACH |
Fault Insertion Unit
General |
Number of channels per unit |
12, 24, or 36 |
Number of channels in series |
Up to 252 |
Channel-to-channel isolation |
100 V |
Channel-to-system isolation |
1 kV |
Power supply |
DC voltage input: 48 V DC ± 5 % |
Power consumption |
40 W max. for 12 channels An additional 25 W for each subsequent set of 12 channels |
Communication interface |
EtherCAT |
Channel Fault Emulation |
Failure type, per channel |
Emulation of short circuit, broken wire, and reverse polarity on battery cell. Emulation of broken wire to BMS |
Physical |
Dimensions |
2U 19” subrack enclosure, depth: 350 mm |
Connectors |
2x RJ45 connectors for communication with the real-time target machine, as well as additional Battery Cell Emulators, Fault Insertion Units, and Temperature Sensor Emulators 12 x, 24 x or 36 x 4-pin Mega-Fit input connectors (Molex part No. 768250004) 12 x, 24 x or 36 x 4-pin Mega-Fit output connectors (Molex part No. 768250004) 1 x 5-pin pluggable MSTB terminal block for Power Input and INTERLOCK (Phoenix part No. 1776728) Refer to order information for the correct item ID depending on the number of channels |
Weight |
100 V |
Environmental |
Operating temperature |
5 °C to 40 °C |
Relative humidity |
5 % to 95 %, non-condensing |
Standards Compliance |
Compliances |
CE, CB, FCC, UK CA EMC: IEC 61326-1 Safety: IEC 61010-1 RoHS, REACH |
Please fill out our configuration form and specify your requirements to receive accurate information for your real-time target solution. We are quick to respond and happy to discuss your needs to provide product and pricing information promptly.