Item ID |
Product Name |
Components |
2I925X |
IO925-0125-1-09 |
- IO925-0125-1-09
- High precision resistor simulation I/O module with 9 channels and resistance range of 1Ω to 31.5Ω, driver configurable in steps of 0.125Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2J925X |
IO925-0125-1-18 |
- IO925-0125-1-18
- High precision resistor simulation I/O module with 18 channels and resistance range of 1Ω to 31.5Ω, driver configurable in steps of 0.125Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2L925X |
IO925-0125-2-09 |
- IO925-0125-2-09
- High precision resistor simulation I/O module with 9 channels and resistance range of 1.5Ω to 472Ω, driver configurable in steps of 0.125Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2M925X |
IO925-0125-3-04 |
- IO925-0125-3-04
- High precision resistor simulation I/O module with 4 channels and resistance range of 2Ω to 6.97kΩ, driver configurable in steps of 0.125Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2N925X |
IO925-0125-3-09 |
- IO925-0125-3-09
- High precision resistor simulation I/O module with 9 channels and resistance range of 2Ω to 6.97kΩ, driver configurable in steps of 0.125Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2O925X |
IO925-0125-4-03 |
- IO925-0125-4-03
- High precision resistor simulation I/O module with 3 channels and resistance range of 2.5Ω to 94.9kΩ, driver configurable in steps of 0.125Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2P925X |
IO925-0125-4-06 |
- IO925-0125-4-06
- High precision resistor simulation I/O module with 6 channels and resistance range of 2.5Ω to 94.9kΩ, driver configurable in steps of 0.125Ω
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2Q925X |
IO925-0125-5-03 |
- IO925-0125-5-03
- High precision resistor simulation I/O module with 3 channels and resistance range of 3Ω to 1.51MΩ, driver configurable in steps of 0.125Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2R925X |
IO925-0125-4-06 |
- IO925-0125-4-06
- High precision resistor simulation I/O module with 6 channels and resistance range of 3Ω to 1.51MΩ, driver configurable in steps of 0.125Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2E925X |
IO925-0250-1-09 |
- IO925-0250-1-09
- High precision resistor simulation I/O module with 9 channels and resistance range of 1Ω to 62.1Ω, driver configurable in steps of 0.25Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2F925X |
IO925-0250-1-18 |
- IO925-0250-1-18
- High precision resistor simulation I/O module with 18 channels and resistance range of 1Ω to 62.1Ω, driver configurable in steps of 0.25Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2G925X |
IO925-0250-2-04 |
- IO925-0250-2-04
- High precision resistor simulation I/O module with 4 channels and resistance range of 1.5Ω to 925Ω, driver configurable in steps of 0.25Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2H925X |
IO925-0250-2-09 |
- IO925-0250-2-09
- High precision resistor simulation I/O module with 9 channels and resistance range of 1.5Ω to 925Ω, driver configurable in steps of 0.25Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2A925X |
IO925-0250-3-04 |
- IO925-0250-3-04
- High precision resistor simulation I/O module with 4 channels and resistance range of 2Ω to 13.6kΩ, driver configurable in steps of 0.25Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2B925X |
IO925-0250-3-09 |
- IO925-0250-3-09
- High precision resistor simulation I/O module with 9 channels and resistance range of 2Ω to 13.6kΩ, driver configurable in steps of 0.25Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2C925X |
IO925-0250-4-03 |
- IO925-0250-4-03
- High precision resistor simulation I/O module with 3 channels and resistance range of 2.5Ω to 189kΩ, driver configurable in steps of 0.25Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2D925X |
IO925-0250-4-06 |
- IO925-0250-4-06
- High precision resistor simulation I/O module with 6 channels and resistance range of 2.5Ω to 189kΩ, driver configurable in steps of 0.25Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2S925X |
IO925-0500-1-09 |
- IO925-0500-1-09
- High precision resistor simulation I/O module with 9 channels and resistance range of 1Ω to 122Ω, driver configurable in steps of 0.50Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2T925X |
IO925-0500-1-18 |
- IO925-0500-1-18
- High precision resistor simulation I/O module with 18 channels and resistance range of 1Ω to 122Ω, driver configurable in steps of 0.50Ω
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2U925X |
IO925-0500-2-04 |
- IO925-0500-2-04
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2V925X |
IO925-0500-2-09 |
- IO925-0500-2-09
- High precision resistor simulation I/O module with 9 channels and resistance range of 1.5Ω to 1.81kΩ, driver configurable in steps of 0.50Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2W925X |
IO925-0500-3-04 |
- IO925-0500-3-04
- High precision resistor simulation I/O module with 4 channels and resistance range of 2Ω to 26.7kΩ, driver configurable in steps of 0.50Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2X925X |
IO925-0500-3-09 |
- IO925-0500-3-09
- High precision resistor simulation I/O module with 9 channels and resistance range of 2Ω to 26.7kΩ, driver configurable in steps of 0.50Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2Y925X |
IO925-0500-4-03 |
- IO925-0500-4-03
- High precision resistor simulation I/O module with 3 channels and resistance range of 2.5Ω to 379kΩ, driver configurable in steps of 0.50Ω
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2Z925X |
IO925-0500-4-06 |
- IO925-0500-4-06
- High precision resistor simulation I/O module with 6 channels and resistance range of 2.5Ω to 379kΩ, driver configurable in steps of 0.50Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2A927X |
IO927-1000-1-09 |
- IO927-1000-1-09
- High precision resistor simulation I/O module with 9 channels and resistance range of 1Ω to 239Ω, driver configurable in steps of 1.00Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2B927X |
IO927-1000-1-18 |
- IO927-1000-1-18
- High precision resistor simulation I/O module with 18 channels and resistance range of 1Ω to 239Ω, driver configurable in steps of 1.00Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2C927X |
IO927-1000-2-04 |
- IO927-1000-2-04
- High precision resistor simulation I/O module with 4 channels and resistance range of 1.5Ω to 3.55kΩ, driver configurable in steps of 1.00Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2D927X |
IO927-1000-2-09 |
- IO927-1000-2-09
- High precision resistor simulation I/O module with 9 channels and resistance range of 1.5Ω to 3.55kΩ, driver configurable in steps of 1.00Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2E927X |
IO927-1000-3-04 |
- IO927-1000-3-04
- High precision resistor simulation I/O module with 4 channels and resistance range of 2Ω to 52.4kΩ, driver configurable in steps of 1.00Ω
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2F927X |
IO927-1000-3-09 |
- IO927-1000-3-09
- High precision resistor simulation I/O module with 9 channels and resistance range of 2Ω to 52.4kΩ, driver configurable in steps of 1.00Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2G927X |
IO927-1000-4-03 |
- IO927-1000-4-03
- High precision resistor simulation I/O module with 3 channels and resistance range of 2.5Ω to 759kΩ, driver configurable in steps of 1.00Ω
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2H927X |
IO927-1000-4-06 |
- IO927-1000-4-06
- High precision resistor simulation I/O module with 6 channels and resistance range of 2.5Ω to 759kΩ, driver configurable in steps of 1.00Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2I927X |
IO927-2000-1-09 |
- IO927-2000-1-09
- High precision resistor simulation I/O module with 9 channels and resistance range of 1Ω to 470Ω, driver configurable in steps of 2.00Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2J927X |
IO927-2000-1-18 |
- IO927-2000-1-18
- High precision resistor simulation I/O module with 18 channels and resistance range of 1Ω to 470Ω, driver configurable in steps of 2.00Ω
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2K927X |
IO927-2000-2-04 |
- IO927-2000-2-04
- High precision resistor simulation I/O module with 4 channels and resistance range of 1.5Ω to 6.97kΩ, driver configurable in steps of 2.00Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2L927X |
IO927-2000-2-09 |
- IO927-2000-2-09
- High precision resistor simulation I/O module with 9 channels and resistance range of 1.5Ω to 6.97kΩ, driver configurable in steps of 2.00Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2M927X |
IO927-2000-3-04 |
- IO927-2000-3-04
- High precision resistor simulation I/O module with 4 channels and resistance range of 2Ω to 102kΩ, driver configurable in steps of 2.00Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2N927X |
IO927-2000-3-09 |
- IO927-2000-3-09
- High precision resistor simulation I/O module with 9 channels and resistance range of 2Ω to 102kΩ, driver configurable in steps of 2.00Ω
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2O927X |
IO927-2000-4-03 |
- IO927-2000-4-03
- High precision resistor simulation I/O module with 3 channels and resistance range of 2.5Ω to 1.51MΩ, driver configurable in steps of 2.00Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|
2P927X |
IO927-2000-4-06 |
- IO927-2000-4-06
- High precision resistor simulation I/O module with 6 channels and resistance range of 2.5Ω to 1.51MΩ, driver configurable in steps of 2.00Ω.
- Driver block library for Simulink® Real-Time™
- Installation into real-time target machine
|